Page Block-Off Plate Installation Insert Installation Block-Off Plate Installation Whenever this appliance is installed with a direct connection a block-off plate, or other non- combustible seal-off device e. This device is used to seal the chimney, insuring no smoke enters the home and providing the chimney system with a seal to promote draft. Fireplace N O T E : Direct connections require installation of an airtight block-off plate or damper adapter see "Block-off Plate Installation" on page Page Operating Your Appliance If the stove top or other area starts to glow red, you are over-firing the stove.
Shut the air control down to low and allow the stove to cool before proceeding. Page Starting A Fire N e v e r use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or "freshen up" a fire in this stove.
Keep all such liquids well away from the stove while it is in use. See the illustration below for details. Use the air control to change the burn rate.
Use large pieces if possible. Let the stove burn on high for 15 minutes to keep the stove hot, then turn the air control to low. In the morning the stove should still be hot, with embers in the coal bed.
Stir the coals and load small pieces of wood to re-ignite the fire, if desired. The blower will come on when the stove is hot - usually 15 to 30 minutes. Page Maintaining Your Appliance Generally, remove ash once it has built up over 1". Follow the directions below to remove ash. Let the stove cool completely at least two hours after the last coal has extinguished.
Place a cloth or cardboard protector over the hearth to catch ash and protect against scratching. The door latch should pull the door against the face of the stove but not so tight as to not allow full handle rotation. If the latch requires adjustment, follow the directions below. Page Yearly Maintenance Make sure the appliance has fully cooled prior to conducting service. To touch up nicks or dulled paint, apply the paint while the appliance is cool.
Stove gasket cement holds it in place. Damage must be repaired to ceiling prior to installation. The chimney must be 15' to 33' tall. See the section "Stove Placement Requirements" for minimum clearances required. Chimney connector sections See the section "Floor Protection Requirements" Page 20 Use the air control to change the burn rate.
Blower Sounds: The blower will make a slight "humm" as it pushes air through the stove. Page 22 Wood Cut wood to length and Store the wood off the ground in a chop into quarters. Allow for airflow around the wood to dry the wood. Apply glass cleaner or soapy water to the inside of the glass. Wipe with newspaper or a paper towel. For Stubborn Creosote: Dip newspaper or a paper towel in cool ashes and wipe it on the glass. The ash Use wood stove gasket cement to re-adhere loose gasket.
Severely frayed or thread-bare gasket should be replaced. D oor Cam Adjustment: To tighten, remove NOTE: Glue the door gasket to the door retainer. Page Firebox Parts Firebox Parts are removed later because they are pinned in place by the floor firebrick. Page 5 Mobile Home This Manual Page 6 Measure side and top clearances from the top plate. Page 10 This distance is the hearth step-up.
The leveling bolts should stick out this far from the Fireplace base of the insert. Hearth The leveling bolts go into the holes at the rear corners of the insert. Page 11 Damper See the dimensions to determine the location of the center of the Firebox flue. Block-Off Plate Template 2" Flanges Measurement "A" for attaching the block-off plate Measurement "B" See the dimensions to determine the location of the center of the flue.
Measurement "C" Page 12 Install a non-combustible cover plate to prevent water from entering the chimney Combustible Mantle Surround Panels See the section "Insert Placement Requirements" for minimum clearances and hearth required. Cap prevents water from entering Flue Liner The liner must be stainless steel connector or flexible vent. Flue Liner Stainless steel chimney connector must Extend 1' past the block-off plate or to the flue liner Airtight Insulated Clean-Out Remove damper or wire it open Block-off plate or damper adapter Page 14 Rotate the door handle.
Page 17 Use the air control to change the burn rate. Page 18 Turn the dial all the way counter- clockwise until it clicks off. Pioneer Heritage PS - Owners. Large Pellet Stoves Yankee - Owners. Yankee PS - Owners. Leyden Pellet Stove - Owners. Deerfield Pellet Stove - Owners. Foxfire - English French. FoxFire PI -- to Owners. Allegiance EF - Owners. Berkshire Berkshire EF - Owners. Berkshire - Double Door - Owners. Berkshire - Owners.