Docsis file creator




















All CMs, regardless of vendor, require configuration files. There are both standard fields and vendor specific fields within the file. The configuration file in its final form is a binary file, and typically a configuration tool is used to create the file. The "client identifier" option MUST be included, with the hardware type set to 1, and the value set to the same 48 bit MAC address as the chaddr field.

The "parameter request list" option MUST be included. The option codes that MUST be included in the list are:. Installation is straight forward: so try it. Next step will be to contact us to see which unbelievable solution we can propose. You will enjoy all the advantages of a cloud solution but also our expertise acquired from more than 15 years inside cable companies We aim to help all cable companies and contribute in DOCSIS never ending innovation and evolution.

No matter the size of your network, try it from now and for 30 days free of charge with a rapid and easy activation. Provisioning The DPS solution makes it possible to create and operate HSD and Voice services defined by an operator in the point-and-click webUI interface designed with the best user experience practice. Designed to perform easy modification, blocking and activation of services as well as changes of service parameters, like the upload speed or max CPE allowed.

The system is compatible with any CMTS manufacturers and most cable modem vendors out-of-box. You can perform detailed analysis of RF parameters from last seven days, watch trends from last year and read online data directly from cable modem and compare it with the whole upstream statistics like US SNR, FEC or amount of logged in CM.

From webUI you can access cable modem logs, perform flap-list diagnostic or compare with other devices running in the same area. Alcatel-Lucent's product provides support to manage cmts devices. EMS will be using old-school snmpv2 and v3 to manage the devices. Plan is to support SDN capabilities on top of existing infrastructure. It is this Diffie-Hellman key initialization and key update mechanism that allows cable companies to authorize data services to customers, and provide data access services through their infrastructure.

This provisioner works great based on a test with Aurora Trident7, but it should work fine with any of the other manufacturers as well. To improve operators services, companies always strive to reduce time and cost of support to the customers by building smarter and smarter softwares. ImageControl accelerates the deployment of new advanced cable services by quickly and seamlessly inventorying customer premises equipment CPE , upgrading modem firmware, and reducing administrative costs by automating complex firmware management functions.

ImageControl also helps minimize errors by centralizing management and automating recurring functions though an intuitive graphical interface. And ImageControl supports subscriber growth by scaling to millions of devices and improves customer satisfaction by ensuring version compatibility with minimal service disruption. IP utilization reports and alerts enable you to proactively manage IP address capacity and single-click allocations simplify subnet, pool and IP address assignment tasks.

Granular administrator controls enable you to delegate DDI tasks to empower site administrators while retaining centralized control. Glenn Waring glenn. Platform independent.

Easy to connect to CRM. Easy extendable. PHP based. It is completely free and open source — GPLv3 hosted at github. Check it out under:. For any potential concerns or suggestions you can reach us at m. Installations, upgrades and migrations.. Cosighter is a capacity planning and signal quality monitoring tool that is designed to make your cable network operations easier.

Cosighter collects, analyzes and summarizes management data by using latest technologies to quickly diagnose issues and measure overall service quality. Skip to main content. Create new account Request new password. You are here Home. Software, Testing and Provisioning Tools. Services Worldwidesupply Installations, upgrades and migrations.. Log in or register to post comments.

Thanks for your response David, the file which I mentioned "bootfile qbp. I need you to assign a different IP range on the client side. Thank you. Same for changing the IP range on the client side. Thanks David for the clarification, Why docsis config file editor not allowing to update the downstream value more than You can't simply copy-paste, since config files are binary, so you'll need to write the binary version with added integrity checks , but you can do that with our DOCSIS Configfile Editor, yes.

I'm able to hit the CM remotely via the mgmt IP, but the credentials I use locally to login do not work. I would like to setup a password via the config file. For DPoG its the same? Hi Jonathan, as already said in the support portal, you need a private mib for that. Hi Pablo, what exactly do you mean?

Hi Guys, here it is my question, how can we enable syslog messages in a cable modem in otder to be sent to a CMTS? Do you have a exaple? As an example, for the syslog server, this would look like the following ipv4 Seem the command is not accepted, but config file is loaded. Any idea what could be the reason?

Hi, we are small ISP in Slovakia. I need to help with a specific problem. If i connect CMTS direct in our switch in server room without microwave , there is speed more than Mbps with similar docsis parameters. But if i test a speed behind a microwave before cmts , the speed is ok, full speed of microwave capacity - like Mbps, 2ms ping. Please, where may be a problem? We try to many changes in cm file, but problem still occurs.

Thanks Andy. Hi I am using SBE now. In my config I didn't limited upload speed. What is going on? I can't fit it. We'll contact you to discuss other options. Best regards, David.



0コメント

  • 1000 / 1000